Thoracolumbar Fixation
Pedicle Screw System
Introductions
VikingSpine™ Pedicle Screw System provides surgeons with a comprehensive range of intraoperative options for reduction of spinal deformities, stabilization of unstable spinal segments, and enhanced fusion. The implants and instrumentation were designed to streamline the operative procedure and to accommodate variations in patient anatomy. This top-loading, low-profile system includes multi-axis pedicle screws, with up to 54 degrees of angulation. The screw seats utilize TorX locking technology, which helps prevent “tulip splay”. The full offering of screw and rod diameters allows the surgeon to tailor the construct to the specific needs of the patient.
System Features and Benefits
VikingSpine™ Pedicle Screw System provides options that allow the surgeon to tailor the construct to the specific needs of the patient. The top-loading, low-profile design helps avoid impingement with adjacent anatomy.
Innovative dovetail set screw design and friction fit tulip screw head design
Assortment of screw diameters and lengths
Color-coded screw heads
Full assortment of instruments
54° of Screw angulations.
Self-taping cannulated screws to easy insertion.
Indications
Degenerative diseases
Spondylolisthesis
Spondylarthrosis
Osteochondrosis
Osteoporosis
Degenerative instabilities
Spinal canal stenosis
Tumour
Spondylitis
Deformities
Scoliosis
Spondylolisthesis
Hyperkyphosis
Hyperlordosis
Trauma
Vertebral body fractures
Revision
Reimplantation
Pseudarthrosis
Contrindications
The patient’s bone condition (ex: massive osteoporosis) making the procedure risky at the level of mechanical anchorage of the implant
Congenital narrow spinal canal
Comminuted fractures affecting several vertebrae
Tumour on several successive vertebrae
Allergy, intolerance and/or hypersensitivity to the
TA6V ELI titanium component
Primary or secondary infection
Local inflammation
Fever, leucocytosis
Obesity
Pregnancy
Mental illness
Congenital abnormal anatomy
Rapidly progressive joint disease, severe osteoporosis
Unsuitable anatomy
Patient with not enough soft tissue to cover the implanted site
Details
Polyaxial & Reduction:
ø7.5 L50
ø7.5 L45
ø7.5 L40
ø7.5 L35
ø7.5 L30
ø6.5 L55
ø6.5 L50
ø6.5 L45
ø6.5 L40
ø6.5 L35
ø6.5 L30
ø5.5 L55
ø5.5 L50
ø5.5 L45
ø5.5 L40
ø5.5 L35
ø5.5 L30
ø4.5 L40
ø4.5 L35
ø4.5 L30
ø4.5 L25
Transverse Connector:
L70-50mm
L60-70mm
L50-60mm
L40-50mm
Rod:
L450mm
L400mm
L300mm
L250mm
L180mm
L170mm
L160mm
L150mm
L140mm
L130mm
L120mm
L110mm
L100mm
L90mm
L80mm
L70mm
L60mm
L50mm
www.viking-spine.com