From [ Ссылка ]
JustAnswer Customer: I have a KitchenAid induction cooktop.
JustAnswer Customer: I was getting f47 error code.
JustAnswer Customer: I ordered the entire power module part number w10857232 installed and programmed it.
JustAnswer Customer: I am only getting one burner to work now.
JustAnswer Customer: The other three just click for a few seconds then turn off.
JustAnswer Customer: Model number is *
Pearl Wilson: Assistant: Can you guesstimate how old your KitchenAid is?
Pearl Wilson: Assistant: And just to clarify, what's the exact model?
JustAnswer Customer: I put the model at the door of my comment.
JustAnswer Customer: Kicu509xxss00.
JustAnswer Customer: Probably about 5-6 years old.
Pearl Wilson: Assistant: Do you plan on doing the work yourself?
JustAnswer Customer: I am a technician so yes
Pearl Wilson: Assistant: Anything else we should know to help you best?
JustAnswer Customer: No
Master Tech: Master Technician: My name is Woody.
Master Tech: Master Technician: I`m sorry to hear that your having issues!
Master Tech: Master Technician: I will do my best to take the information that you provide to me and make a Diagnosis for you to be able to repair your own Appliance.
Master Tech: Master Technician: I`m also be assisting you along with other customers so there may be a delay in responses to do not panic just wait for my reply!
Master Tech: Master Technician: NOTE : The website will send you a prompt for a PHONE CALL And POP UPS those are NOT from me , so if you do not want me to call you then please IGNORE IT !
Master Tech: Master Technician: Give me a few minutes to pull up information on this model.
Master Tech: Master Technician: ok for the F47 error code the repair suggested is .
Master Tech: Master Technician: 1.
Master Tech: Master Technician: Disconnect power.
Master Tech: Master Technician: 2.
Master Tech: Master Technician: Check that the cables between the User Interface and the power control board are not damaged and are firmly plugged in.
Master Tech: Master Technician: 3.
Master Tech: Master Technician: Replace all parts and panels before operating.
Master Tech: Master Technician: 4.
Master Tech: Master Technician: Reconnect power and check that it is working.
Master Tech: Master Technician: If it is not working, disconnect power and replace the cables between the User Interface and the power control board.
Master Tech: Master Technician: 5.
Master Tech: Master Technician: Replace all parts and panels before operating.
Master Tech: Master Technician: 6.
Master Tech: Master Technician: Reconnect power and check that it is working.
Master Tech: Master Technician: If it is not working, go to Step 7.
Master Tech: Master Technician: 7.
Master Tech: Master Technician: Disconnect power.
Master Tech: Master Technician: 8.
Master Tech: Master Technician: Check the continuity between black luge at the terminal block and both L2 terminals on the EMI board.
Master Tech: Master Technician: If there is not continuity on one or both of these lines, replace the thermofuse harness.
Master Tech: Master Technician: 9.
Master Tech: Master Technician: Replace all parts and panels before operating.
Master Tech: Master Technician: 10.
Master Tech: Master Technician: Reconnect power and check that it is working.
Master Tech: Master Technician: If it is not working, go to Step 11.
Master Tech: Master Technician: 11.
Master Tech: Master Technician: Disconnect power.
Master Tech: Master Technician: 12.
Master Tech: Master Technician: Check the continuity of the fuses on the EMI board.
Master Tech: Master Technician: If either of the fuses is blown, replace with a new one.
Master Tech: Master Technician: 13.
Master Tech: Master Technician: Replace all parts and panels before operating.
Master Tech: Master Technician: 14.
Master Tech: Master Technician: Reconnect power and check that it is working.
Master Tech: Master Technician: If it is not working, go to Step 15.
Master Tech: Master Technician: 15.
Master Tech: Master Technician: Disconnect power.
Master Tech: Master Technician: 16.
Master Tech: Master Technician: Change both control boards.
Master Tech: Master Technician: 17.
Master Tech: Master Technician: Replace all parts and panels before operating.
Master Tech: Master Technician: 18.
Master Tech: Master Technician: Reconnect power and reconfigure the cooktop following the directions in “Manual Configuration Mode.” Check that it is working.
Master Tech: Master Technician: If it is not working, go to Step 19.
Master Tech: Master Technician: 19.
Master Tech: Master Technician: Disconnect power.
Master Tech: Master Technician: 20.
Master Tech: Master Technician: Change the User Interface 21.
Master Tech: Master Technician: Replace all parts and panels before operating.
![](https://i.ytimg.com/vi/89rzJx1qIvk/maxresdefault.jpg)