A forward reverse motor control starter with limit switches is a more advanced version of the previous system. In this system, the motor is started and stopped using a motor starter, which is controlled by limit switches. The system can be used to start and stop the motor in both forward and reverse directions, and to stop the motor when it reaches a certain point.
To implement this system, you will need the following components:
Motor: The motor that you want to control in both forward and reverse directions.
Motor starter: A device that is used to start and stop the motor. The motor starter should have a forward and reverse contactor.
Limit switches: These switches are used to control the position of the motor and to stop the motor when it reaches a certain point. There are two types of limit switches: normally open (NO) and normally closed (NC). The NO switch is open until it is actuated, while the NC switch is closed until it is actuated.
Power supply: A power supply is needed to provide the necessary power to the motor starter and the motor.
Here is a step-by-step guide to wiring and programming the system:
Connect the power supply to the motor starter and the motor.
Connect the NO limit switch to the control circuit of the forward contactor, and the NC limit switch to the control circuit of the reverse contactor.
Connect the output of the motor starter to the motor.
Program the motor starter to respond to the limit switches. When the NO limit switch is actuated, the forward contactor should open, stopping the motor from rotating in the forward direction. When the NC limit switch is actuated, the reverse contactor should open, stopping the motor from rotating in the reverse direction.
Test the system to ensure that it is working as expected.
When the motor is started in the forward direction, the NO limit switch will be actuated when the motor reaches its maximum forward position, and the forward contactor will open, stopping the motor. Similarly, when the motor is started in the reverse direction, the NC limit switch will be actuated when the motor reaches its maximum reverse position, and the reverse contactor will open, stopping the motor. The limit switches can also be used to stop the motor at any intermediate position by wiring them to the motor starter's stop button.
..
Your Queries:-
1 Forward Reverse Motor Control with limit switch
2 Automatic Reverse Forward with limit Switch
3 Automatic Reverse Forward motor control with limit Switch
4 Reverse Forward motor control circuit diagram with limit Switch
5 Forward Reverse Motor Control wiring with limit switch
6 Motor control
7 Motor starter
8 Limit switches
9 Forward reverse motor control
10 Control circuit
11 Electrical wiring
12 Electrical control system
13 Industrial automation
14 Motor overload protection
15 Electrical safety
16 Circuit diagram
17 Electrical engineering
18 reverse forward starter control with limit switch
19 reverse forward starter
20 forward reverse starter
21 reverse forward starter control wiring
22 automatic reverse forward starter control with limit switch
23 limit switch
24 limit switch connection
25 motor starter
26 reverse forward starter control
27 reverse forward starter with limit switch
28 reverse forward starter connection with limit switch
29 automatic reverse forward starter
30 forward reverse
31 motor control
..
..
Get More Great Videos - 🔔Subscribe →MY CHANNEL
My Other Videos links..
DOL Starter Connection for 3 Phase Motor || 3 Phase Direct Online Starter ||DOL Starter Power Wiring
[ Ссылка ]
Automatic Transfer Switch ATS With time Delay | ATS Panel Wiring | ATS Connection in Urdu Hindi
[ Ссылка ]
Star Delta Starter Power Connection with Wiring diagram || 3 phase motor connection || power wiring
[ Ссылка ]
Cable Size Calculation | What is Sqmm in Cable | electrical interview question
[ Ссылка ]
..
#forwardreverse #limitswitch #motorstarter
#onlineelectricwork #electricworks #basicelectrical #diagram #basicelectricalengineeringvideotutorials
![](https://i.ytimg.com/vi/kTBH_8X16r8/maxresdefault.jpg)