This short video covers some of the do's and don'ts which are very obvious to many people when installing a Sunsynk hybrid inverter.
DO
Always install the inverter in a well-ventilated area
Check your supply voltage, and ensure you have a good grounding and a good neutral ( a floating neutral can be very dangerous )
Make sure that the inverter is actually switched, on it can appear to be working even when it's not switched on.
If you're using a timer ensure that the clock is set to the correct time
Always check you have good communication with your battery before completing the commissioning of any system, if you don't have good communication the system will not work.
Check your battery charging currents
Check the inverter limiters
When paralleling inverters in 3 Phase check that the true master is on the start of the rotation sequence
If you need to charge the batteries from either a generator or the AC you must program an inverter to do this it will not do it automatically
Don't
Try never to exceed the VOC for 450 V
Never join in MPPT's together this will damage them.
Don't try to parallel inverters without communication between the inverters this could cause damage
Never run the inverter without the correct protection equipment
Never run an inverter unless it is grounded correctly
Never run an inverter without a CT coil is very important even if using a generator
Advice when installing a Sunsynk Hybrid Inverter
Теги
Deyebestbillchargercheapcontrollercustomempfreegeneratorgridhomehow tohow to program sunsynk inverterhybridhybrid inverterinstallinverterlgmenusoff gridpowerpower inverterpower inverter for carpower inverter for homeprepperprogrammingshipsol arksolarsolar panelssolar panels for homesolar powersolar systemsolaredgesun synk inverters parallel dip switchessunsynksunsynk inverter wind turbine setupthewind